Superheat on 410a - An R-22 evaporator running at 40F saturation temperature will have a corresponding pressure of 68.5 psig. Should the suction pressure drop below 57 psig, the coil temperature will drop below 32F causing moisture in the air to freeze on it (see Figure 4) causing no end of trouble. A R-410A evaporator running below 100 psig will freeze-up …

 
In this HVAC Training Video, I Show How to Check the Refrigerant Charge on an R-410A Air Conditioner using the Total Superheat Method. I First Show How to Fi... . Haralson county tax commissioner

R410A unit by lining up the pressure with the appropriate refrigerant scale. In this example the Sat temp is 43 degrees. Subtract the two and you have 10 degrees of Superheat. SUBCOOL The Saturation temperature for Subcooling is acquired from the high side gauge. In this example the Sat Temp is about 110 degrees. Next is to “Minus Liquid Line ... Calculate. This free online tool allows HVAC professionals to quickly calculate Superheat and Subcooling measurements for both R22 & R410A refrigerants.Superheat is especially important in HVAC systems containing a fixed metering device, and superheat measurement is the primary method to determine proper refrigerant charge. The Air Conditioning Process To understand what superheat is, one must understand the air conditioning process.Updated: Dec 14, 2022 In this article, we will define both superheat and total superheat, calculate total superheat, explain how to use total superheat to check the …9 superheat & subcooling scenarios. LOW CHARGE = High superheat. Low suction pressure, indoor TD, subcooling, head pressure & compressor current draw. OVER CHARGE = Low superheat. Normal indoor TD. High suction pressure, subcooling, head pressure & compressor current draw. LOW INDOOR AIR FLOW = Low superheat & …We do not make any claims to accuracy and are not liable for any calculations or miscalculations. It is up to you to compare these to your own formulas. These calculators are free to use but use them at your own risk. Our Free Calculators can be used to find target superheat, refrigerant weight for charging, and determining airflow CFM on a ...When an air-conditioning system operates in a vacuum, which of the following is true? Air will be pulled into the system. The condensing pressure is 417.4 psig for R-410A and the condenser outlet temperature is 108 degrees Fahrenheit. How much subcooling is there in the condenser? 12 degrees Fahrenheit.R-404A, R-407C, R-408A, R-409A, R-410A, R-422D, and R-507 are based on vapor free 100°F liquid refrigerant enter-ing the expansion valve, a maximum opening superheat of 7°F, and a standard factory air test superheat setting. A discussion of the relationship between valve capacities and superheat set-tings can be found in Bulletin 10-9.It is a clear, colorless, non-toxic and non-irritating liquid. R-410A is a 50:50 blend of R-32 and R-125. The boiling point at atmospheric pressure is -62.9°F. A few of the important principles that make the refrigeration cycle possible are: heat always flows from a warmer to a cooler body. by ziauddin khan khan , Electrical and supervisor , Majal Service Company. …See more. hi, anyone familar with R410A. For air conditioning system, R22 pressure in discharge is250psi and suction in67psi. But for R410A pressure will be more higher that R22. So what pressure is normal for air-conditioning systems. Besides that normal R22 ...Jun 25, 2016 · The liquid pressure should be 385-395 and the suction pressure should be about 138 but will probably be a few psi lower since it's so cool in the space. The sub-cool should be 11 deg. F +/- 1.5 deg. F. Temp (°F) Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Temp (°F) Temp (°C) Pressure Temp (°F) Pressure Temp (°C)I have no experience with 40 ton equipment, but superheat and subcooling values are generally consistent regardless of the type refrigerant. Which would suggest 26 is high for the superheat and 61 is way high for the subcooling. The suction pressure and SST is normal, but 350 could be high for the head depending on the unit SEER.recommended superheat obtained from the table by more than 5°F, add 2-4 ounces of refrigerant, and wait at least ten minutes before repeating this superheat procedure. 9. If the actual superheat is less than the ideal by more than 5°F, remove 2-4 ounces refrigerant, and wait at least ten minutes before measuring superheat again. Refrig-Usually, target superheat on a TXV system will be 5°F- 15°F (2.75K – 8.25K) at the outlet of the evaporator where the TXV bulb is located. On a piston system, the target superheat is calculated using a superheat chart and measuring and plotting the outdoor dry bulb temperature and the indoor wet-bulb temperature.Calculate. This free online tool allows HVAC professionals to quickly calculate Superheat and Subcooling measurements for both R22 & R410A refrigerants.An R-22 evaporator running at 40F saturation temperature will have a corresponding pressure of 68.5 psig. Should the suction pressure drop below 57 psig, the coil temperature will drop below 32F causing moisture in the air to freeze on it (see Figure 4) causing no end of trouble. A R-410A evaporator running below 100 psig will freeze-up …In this HVAC Refrigerant Charging Video I go over what it means to have low R22 Freon or Low R410A Suction Vapor Pressure along with a Low Superheat. I expla...The clamp-on thermometer shows that the saturated refrigerant temperature is 56°F. Here's how to calculate superheat for this system: Superheat (R-410A) = 56°F - 45°F = 11°F. We see that we have calculated 11°F superheat for this system.From the Goodman manual for that model. Outside drybulb 95F inside drybulb 80F. Hi pressure = 335 Psig, Lo pressure 130 Psig. Which is 20-30 psi off on both. But I was under the assumption if it where low on 410a there would be high superheat and high subcooling. Like I said I’m new. With the excessive subcooling and no superheat, I am …compressor ZP42 (R410A) has been analyzed. 2 3 Pure Compressor Analysis: R410A and R407C show very similar performances with a slight advantage of R407C at higher pressure ratio, i.e. condition 2 and 3 in the above graphs. R410A compressors operate with a higher discharge temperature and therefore utilize unique engineering solutions to feature ... R22 and R410a Low Pressure, High Superheat, Refrigerant Charging Problem Explained! Supervision is needed by a licensed HVAC Tech before doing this as ...Calculate superheat R410a Superheat charts (Cooling, NON-TXV) Instructions Measure wet bulb temperature with a sling psychrometer or a temperature and humidity thermistor. Use a digital thermometer for all temperature measurements. Do NOT use mercury or dial type thermometers.Temp (°F) Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Temp (°F) Temp (°C) Pressure Temp (°F) Pressure Temp (°C)Target Superheat Seems High - 24F On R410A Piston Metered System : r/hvacadvice There seems to be some confusion here. I calculated the target superheat to be 24F using this online calculator . That means theoretically, it should… Advertisement Coins 0 coins Premium Powerups Explore GamingForane 410A Pressure Temperature Chart Forane 410A, R-410A, Pressure Temperature Chart, PT Chart, HVAC, refrigeration, air conditioning, refrigerant gas•The TEV will maintain design superheat under a variety of conditions •For this reason, these systems must be CHARGED using sub-cooling •Proper sub-cooling will maintain a positive liquid seal at the TEV entrance •Determine the required sub-cooling from the IO or the unit datasheet (usually from about 7°F to about 12°FLearn how to use the testo 550s and 557s digital manifolds with this comprehensive instruction manual in PDF format. Find out how to connect, measure, and troubleshoot with these smart devices.compressor ZP42 (R410A) has been analyzed. 2 3 Pure Compressor Analysis: R410A and R407C show very similar performances with a slight advantage of R407C at higher pressure ratio, i.e. condition 2 and 3 in the above graphs. R410A compressors operate with a higher discharge temperature and therefore utilize unique engineering solutions to feature ... But the best way to troubleshoot low suction pressure is by checking for superheat. This will indicate whether or not low suction pressure is caused by insufficient heat getting to the evaporator coil. To check superheat, follow these simple steps below. 1. Use a thermostat that is specifically designed to take pipe temperature. 2.Refrigerants that fractionate, such as R-410A, must be charged as liquid to prevent the separation of the refrigerant. How does an undercharge affect the superheat of a fixed restriction system? An undercharge will increase system superheat.R-410A AC Unit Checked with Superheat: 4 Scenarios, Low Charge through Overcharged! - YouTube 0:00 / 12:57 In this HVAC Video, I Show SEVERELY UNDERCHARGED, UNDERCHARGED, CORRECTLY CHARGED,... Quick Tip #9: Superheating and Subcooling. Fully understanding superheat and subcooling is the key to a refrigeration system performing at its optimum level. Closed captioning is available for this video. To activate this feature, play the video and then select “English” from the menu (CC icon) in the upper left corner of the video player.Negative Superheat. Superheat is the temperature gained in the refrigerant once it has completely boiled into a vapor. When it is still boiling, it will be in a mixed state and will be at saturation temperature for that given pressure. Zero superheat is something you will often see when a system has a flooded coil; zero superheat indicates that ...Remember that the discharge line sees all of the superheat coming to the compressor, the electric motor heat generated, and the heat of compression. The absolute limit that any discharge temperature should be when measured at a distance of about 3 inches from the compressor on the discharge line is 225 degrees. The back of the …Adjust and optimize superheat in less than 15 minutes. TXV Superheat Tuner is now part of Ref Tools, the essential, all-in-one mobile app for air conditioning and refrigeration technicians. Ref Tools gives you access to …If the metering device is a fixed orifice such as a piston or capillary tube, the refrigerant charge of the system can be checked with Total Superheat. If the metering device is a TXV then the refrigerant charge can be checked with Subcooling. See the Picture below. If the unit has a TXV, check for the Target Subcooling posted at the outdoor unit.How to check, measure, and read superheat and subcooling on a central air conditioner unit. In this video I do not go into the details of superheat and subco...We would like to show you a description here but the site won’t allow us.Proper performance of heat pumps and air conditioners are determined by many factors, but chief among them is proper refrigerant chargeR-134A is another commonly used refrigerant we have to calculate superheat for. Let’s say we have a 4-ton 16 SEER AC unit, and we measure 60 psi pressure (equal to 62°F temperature, according to this R-134A PT chart) with the gauge, and the thermometer shows us 80°F. Here is the R-134A superheat … See moreBased on historic sliding cardboard charge calculators, this app allows contractors to easily calculate the correct system refrigerant charge for R-22, R-410A, R-32, R-407C, R-134a, R-452B, R-454B, R-438A, R-422B, R-427A, R-421A, R-404A, R-290, R-449A, R-448A, and R-407A. Contractors can simply choose Superheat, Subcooling, or …Measuring Superheat and Subcool Our Technical department has asked that certain information be documented prior to calling them for help on refrigeration problems. Superheat and Subcooling are vital signs of the system in the same way the doctor uses blood pressure to assess someone’s health. The request may come in a format …What should the suction line temp be for a 410a system? Im measuring mine around 80F after the system runs for a bit (90-92F outside, 76-77F inside), which from what ive read is too hot. Unit is ground level and in the shade. The AC works ok but has difficulty cooling below 75F. Inlet temp at air filter (recently replaced) stabilizes around 78-80 with …Follow heat as it moves through the system to see if the system is or is not performing as it should. That means understanding and measuring all three types of superheat: evaporator, total, and duct system. 1. Evaporator superheat. To measure evaporator (indoor coil) superheat, first measure the suction line temperature at the evaporator outlet.Feb 5, 2017 · In this HVAC Refrigerant Charging Video I Explain how to Check and Measure the Superheat and Subcooling Charging Processes for R22 and R410A freon. I show yo... If you'd like to support the channel, you can do so by shopping for whatever you need on Amazon through this link, http://amzn.to/2lEadp4Dirty Maintenance Sh...Set a bottle of virgin 410a refrigerant in a room with a stable temperature, then hook up your gauges. Adjust your gauges to the room temperature. ... If the superheat is too high, then the system is undercharged, add refrigerant. Hvac tech working on a condensing unit rooftop Charging a A/C system by subcooling. Determine your target ...What should my superheat be on a 410a system? For most systems, 20F to 25F should be measured near the compressor and 10F at the evaporator. The system has 10F of superheat if the pressure is 45 psi and the temp is 32F.What is the target superheat for R-410A in this situation? Let’s use the target superheat formula and calculate this manually: Target Superheat (R-410A) = (3 × 69°F – 80°F – …R-134A is another commonly used refrigerant we have to calculate superheat for. Let’s say we have a 4-ton 16 SEER AC unit, and we measure 60 psi pressure (equal to 62°F temperature, according to this R-134A PT chart) with the gauge, and the thermometer shows us 80°F. Here is the R-134A superheat … See moreR-410A AC Unit Checked with Superheat: 4 Scenarios, Low Charge through Overcharged! - YouTube 0:00 / 12:57 In this HVAC Video, I Show SEVERELY UNDERCHARGED, UNDERCHARGED, CORRECTLY CHARGED,...If you'd like to support the channel, you can do so by shopping for whatever you need on Amazon through this link, http://amzn.to/2lEadp4Dirty Maintenance Sh...Proper performance of heat pumps and air conditioners are determined by many factors, but chief among them is proper refrigerant chargeJul 7, 2019 · Charging a A/C system by subcooling. Determine your target subcooling. This is usually displayed on the back of the nameplate, located on your condensing unit. If not, 10-15 degrees F will get you ballpark range. With the unit running, connect your high side refrigerant gauge, to the liquid line port, or fitting. 8.22K subscribers. R410A system has high superheat, thus low on gas. The run wattage is lower than normal too. Fixed orifice system. One textbook mentions that a 3 degree higher than normal ...Based on the (attached) chart from the outdoor condensing unit I was at 8 degrees superheat ... I am charging my heat pump it is an r410a and its about 90 degrees outside i have gotten the low side up from about 100psi to 130 and the high side from around 300psi to 340-50 is this about right wha ...Mar 11, 2017 · LINE TEMP. - SAT. SUCT. TEMP. Saturated Suction Temperature Pressure Sat. Evap. Temp. INSTALL Thermometer/Thermocouple INSTALLED ON THE SUCTION LINE (LARGER OF TWO COPPER LINES ) Using Superheat Table Excessive or high superheat is an indication of insufficient refrigerant in the evaporator coil for the heat load present. This could mean that not enough.Superheat and subcooling calculations can be calculated the same way we have always done with R-22 refrigerant. The only difference will be the higher pressure-temperature relationship when reading the temperature-pressure chart. The temperature glide for R-410A is only 0.3 degrees F and can be ignored, and fractionation is not a …Apr 25, 2017 · Fix your HVAC orifice with a fixed orifice metering device. We'll identify different superheat chart measuring systems like the R22 superheat chart or the R410a charging chart. We'll also explain how the 410a charging chart can help you fix your HVAC. Discover how to fix your HVAC orifice issues with HVAC Brain. Calculate superheat R410a Superheat charts (Cooling, NON-TXV) Instructions Measure wet bulb temperature with a sling psychrometer or a temperature and humidity thermistor. Use a digital thermometer for all temperature measurements. Do NOT use mercury or dial type thermometers.Oct 1, 2021 - In this HVAC Training Video, I Show How to Check the Refrigerant Charge on an R-410A Air Conditioner using the Total Superheat Method.To calculate superheat, subtract the saturation temperature from the actual temperature. Superheat is important in refrigeration and air conditioning systems to ensure proper …Based on the (attached) chart from the outdoor condensing unit I was at 8 degrees superheat ... I am charging my heat pump it is an r410a and its about 90 degrees outside i have gotten the low side up from about 100psi to 130 and the high side from around 300psi to 340-50 is this about right wha ...We would like to show you a description here but the site won't allow us.Refrigerant R-410A Pressure Temperature Chart - This R410A PT Chart will help you when charging a system that utilizes R-410A. Furthermore, R410A is an HFC and is commonly used in residential and light commercial HVAC equipment for air conditioners and heat pump systems. Additionally, it widely replaces HCFC R-22 which was mandated by …What is a good superheat and subcooling on 410a? The superheat of your heating and cooling system should be 10F at the evaporator. If a thermostatic expansion valve is present (TXV), the subcooling target range should be between 10F and 18F. Your compressor's temperature should sit between 20-25 degrees Fahrenheit. Refrigerants that fractionate, such as R-410A, must be charged as liquid to prevent the separation of the refrigerant. How does an undercharge affect the superheat of a fixed restriction system? An undercharge will increase system superheat.Quick Tip #9: Superheating and Subcooling. Fully understanding superheat and subcooling is the key to a refrigeration system performing at its optimum level. Closed captioning is available for this video. To activate this feature, play the video and then select “English” from the menu (CC icon) in the upper left corner of the video player. What is a good superheat and subcooling on 410a? The superheat of your heating and cooling system should be 10F at the evaporator. If a thermostatic expansion valve is present (TXV), the subcooling target range should be between 10F and 18F. Your compressor's temperature should sit between 20-25 degrees Fahrenheit.High Temp or A/C systems to run 6-14°F of superheat. Medium Temp - 5-10°F. Low Temp - 4-10°F. Some ice machines and other specialty refrigeration may be as low as 3°F of superheatStep 3. Subtract the evaporator saturation temperature from the thermocouple temperature. This difference is the system superheat. This shows the temperature rise above the bubble point temperature of the system. Review the operating specifications for your system to determine the proper superheat. Inadequate superheat can cause liquid ...Examples of these blends are R-410A, R-404A, as well as many others. As noted earlier, as azeotropic and near-azeotropic refrigerant blends phase change through the length of the evaporator and/or condenser heat exchanger, there will be a change in their composition by preferential evaporation or condensation of the more or less volatile …What is a Good Superheat for 410a? For a refrigeration system using R-410A refrigerant, a good superheat range is typically between 8 to 12 degrees Fahrenheit. This range ensures that the refrigerant is fully evaporated before entering the compressor, optimizing system performance and efficiency.You can also use the R-410A PT chart to adequately calculate the superheat, total superheat, and subcooling temperatures. Below you will find two charts: 410A chart for degrees Fahrenheit (°F) and 410A chart for degrees Celsius (°C).In those cases, you would typically notice a low suction pressure and a low superheat. In heat mode, a dirty air filter causes low airflow across the condenser. That can cause extremely high head pressure. In heat mode, a dirty outdoor coil can cause a low suction pressure. ... Less than 35 remove Freon and more than 50 add Freon and works …If the metering device is a fixed orifice such as a piston or capillary tube, the refrigerant charge of the system can be checked with Total Superheat. If the metering device is a TXV then the refrigerant charge can be checked with Subcooling. See the Picture below. If the unit has a TXV, check for the Target Subcooling posted at the outdoor unit.I have a 40 ton AAON rooftop unit with copeland scroll compressors running on 410a refrigerant. I was wondering what my SH and SC should be. I have 132 psi suction and 350 psi discharge and am getting a 26 deg superheat and a 61 deg subcool. It has a TXV. My outdoor temp is 80 deg and return air temp of 72.Carrier’s Puron® Quick Reference Guide mandates the following: “Use recovery machines designated for R-410A.”. “When charging 410A (liquid refrigerant only), use a commercial-type metering device in the manifold hose when charging into the suction line with the compressor operating.”. “Manifold sets should be a minimum 700 psig on ...Figure 1 is an example of a superheat-charging curve instead of a table. The curve is based on 400-cfm/ton airflow at 50% relative humidity across the evaporator coil. The steps to charge a system according to this curve are listed below. 1. Measure indoor drybulb temperature (DBT).As we will see in the R-22 and R-410A examples at the end, target superheat for a system using R-22 and the target superheat for a system using R-410A (or any other refrigerant) are the same. Only the DB and WB temperatures determine the target superheat. Here is the formula we use to calculate superheat: Target Superheat = (3 × TWet Bulb ...for Suva® 410A, R = 0.11455 kJ/kg • K One atmosphere = 101.325 kPa Reference point for enthalpy and entropy: hf = 200 kJ/kg at 0°C sf = 1 kJ/kg • K at 0°C Equations 1. Conversion FactorsŠSI Units to IP Units Properties listed in the following thermodynamic tables in SI units can be converted to I/P units using the conversion factors ...28 Apr 2017 ... It will depend on the system and metering device. For a TXV anything between 5-20 is pretty normal and I leave it alone. 30 is too high for a ...

Can calculate target superheat for fixed orifice expansion devices, superheat and subcooling for 26 refrigerants, airflow calculations and psychrometric calculations to aid with field service of HVACR equipment. Detailed instructions on using the app may be viewed by swiping right after opening the app. Updated on. Sep 1, 2023. Tools. Data safety.. Costco wholesale 3600 e main st waterbury ct 06705

superheat on 410a

Superheat lets you know if the correct amount of refrigerant is being fed into the evaporator. If your Superheat temperature is too high then not enough refrigerant is being fed in. ... (R-410A, R-404A, & R-134A are excluded from this.) This helps us keep compliant and prevents any and all future headaches for you or your company down the …Apr 8, 2018 · Once the refrigerant has boiled to a vapor then any temperature above and beyond the boiling point is known as the Superheat. In other words, Superheat is any temperature of a gas that is above the boiling point for that liquid. The reason that Superheat is so important to measure is that it can give you a direct indicator as to what is wrong ... Carrier’s Puron® Quick Reference Guide mandates the following: “Use recovery machines designated for R-410A.”. “When charging 410A (liquid refrigerant only), use a commercial-type metering device in the manifold hose when charging into the suction line with the compressor operating.”. “Manifold sets should be a minimum 700 psig on ...Temp (°F) Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Temp (°F) Temp (°C) Pressure Temp (°F) Pressure Temp (°C)If you'd like to support the channel, you can do so by shopping for whatever you need on Amazon through this link, http://amzn.to/2lEadp4Dirty Maintenance Sh...In this HVAC Video, I Show How to Find The Target Superheat on an R-410A Air Conditioner with a Piston Fixed Orifice Metering Device.Low superheat indicates an excess of liquid refrigerant in the evaporator coil for the heat load present. • This means either too much refrigerant is ...When an air-conditioning system operates in a vacuum, which of the following is true? Air will be pulled into the system. The condensing pressure is 417.4 psig for R-410A and the condenser outlet temperature is 108 degrees Fahrenheit. How much subcooling is there in the condenser? 12 degrees Fahrenheit.4. When ambient air temp (Outside air temp) is 75-85 degrees the superheat should be 12-15 degrees, if the ambient temperature is 85 degrees or over the superheat should be 8-12 degrees. 5. If superheat is low then flooding the evaporator. Note: Do not adjust charge yet. 6. If superheat is high then starving the evaporator. Note: Do not adjust ...The sensing bulb should be mounted snuggly to the suction line on the evaporator outlet at the 9:00 or 3:00 position for smaller suction lines 5/8" or less. For suction lines 7/8" and larger the bulb should be mounted at the 4:00 or 8:00 position. Adjustments may be needed on a new system at startup, especially when you have long line runs.Feb 2, 2023 · How to check, measure, and read superheat and subcooling on a central air conditioner unit. In this video I do not go into the details of superheat and subcooling, the science behind it and how it works. This is not a troubleshooting or diagnosing video, I simply show how to measure it and provide the simple formula needed to calculate the ... •The TEV will maintain design superheat under a variety of conditions •For this reason, these systems must be CHARGED using sub-cooling •Proper sub-cooling will maintain a positive liquid seal at the TEV entrance •Determine the required sub-cooling from the IO or the unit datasheet (usually from about 7°F to about 12°FTake the return dry bulb (DB) and subtract 35°F (DTD); this is your target coil temperature difference. If the system has a TXV, add in 10° for superheat; if it is a fixed orifice (piston), then add in the target superheat based on a superheat chart or using the HVAC School app. This gives you a target suction line temperature at the ...In this HVAC Training Video, I Show How to Check the Refrigerant Charge on an R-410A Air Conditioner using the Total Superheat Method. I First Show How to Fi...from the temperature measured by our thermometer (superheated vapor temp.). Quick Example: Let's say that we have a 3-ton 16 SEER AC are using R-410A ...We will first examine the low-pressure side of the system, otherwise known as the vapor or suction line. During air conditioning mode, the pressure on the vapor line of an R-410A system will be somewhere between 102 to 145 PSIG. If the system had R-22, the vapor pressure would be between 58 to 85 PSIG but these pressures will be dependent …September 14, 2001. The dire ramifications of under- and overcharging an air conditioner or heat pump were covered last month ("Using the Superheat Method to Charge A/C Systems,"The News, Aug. 13, page 1). The first installment also contained a basic explanation of what superheat is and what it tells you about the condition of the …Superheat lets you know if the correct amount of refrigerant is being fed into the evaporator. If your Superheat temperature is too high then not enough refrigerant is being fed in. ... (R-410A, R-404A, & R-134A are excluded from this.) This helps us keep compliant and prevents any and all future headaches for you or your company down the …for Suva® 410A, R = 0.11455 kJ/kg • K One atmosphere = 101.325 kPa Reference point for enthalpy and entropy: hf = 200 kJ/kg at 0°C sf = 1 kJ/kg • K at 0°C Equations 1. Conversion FactorsŠSI Units to IP Units Properties listed in the following thermodynamic tables in SI units can be converted to I/P units using the conversion factors ....